水利翻譯節(jié)選
Along with moving down of water tunnel, axis of diversion tunnel should be moved to that of the water tunnel as it was. As the elevation of the base plate of diversion tunnel is about 20m lower than that of the water tunnel, the increase of rock burial depth in the hole and the melioration of surrounding rock will be basically satisfied with the requirements of the constitution of diversion tunnel. It is mainly consisted with face slab, plinth, upstream steady protection area, upstream coverage area and other parts. All un-processed metal surface exposed in the air will be shined by sand blasting and printing with two layers of rust inhibiting primer (lead is prohibited), and the thickness of each paint film should not less than 50×10-6m and no less than 75×10-6m after completely dry of the final factory antirust painting. The condensation purpose surface should be painted with appropriate anti-condensation coating.
在引水隧洞下移后,將導(dǎo)流洞軸線移至原引水洞的軸線位置,由于導(dǎo)流洞底板高程較引水洞底板高程低約20m,洞室?guī)r石埋深增加,洞室圍巖巖體質(zhì)量變好,可基本滿足導(dǎo)流洞成洞。主要由面板、趾板及上游蓋重區(qū)、上游鋪蓋區(qū)、等部分組成。所有暴露在大氣中的未加工金屬表面,用噴砂清理到發(fā)亮,并刷2層防銹底漆(不得含鉛),每層漆膜厚度不小于50×10-6m,而最后一道工廠防銹涂料完全干燥后,漆膜厚度不得小于75×10-6m,對(duì)受冷凝作用的表面應(yīng)涂上合適的防結(jié)露涂層。
Standard paint sold by the seller also applied to various small ancillary equipments, such as small power motors, contactors, meters, pressure switches and similar small devices.
賣(mài)方的標(biāo)準(zhǔn)油漆也應(yīng)適用于各種小的輔助設(shè)備,例如:小功率電動(dòng)機(jī)、接觸器、表計(jì)、壓力開(kāi)關(guān)和類似的小型設(shè)備。
The AVR using dual digital channel, with a micro-adjust and improvement characteristics of the generator transient stability. It has manual and automatic dual-channel and independent of each other, each channel could be shut down at any time for maintenance. The spare channel has the capacity of tracking each other thus to ensure bumpless transfer. Connection of AVR and DCS enables remote operation of the control room of the AVR.
AVR采用雙通道數(shù)字式,具有微調(diào)節(jié)和提高發(fā)電機(jī)暫態(tài)穩(wěn)定的特性。具有手動(dòng)和雙自動(dòng)通道,各通道之間相互獨(dú)立,可隨時(shí)停用任一通道進(jìn)行檢修。各備用通道可相互跟蹤,保證無(wú)擾動(dòng)切換。AVR與DCS接口實(shí)現(xiàn)控制室內(nèi)對(duì)AVR的遠(yuǎn)方操作。
Small current grounding line applied the principle of zero power direction, and it is calculated by five times of selected harmonic voltage, current or fundamental voltage and current, capacitor current of breakdown occurred is behind U0 90°, and the capacitor current leads U0 90° in the opposite case, the grounding line selection principle of the direction of the zero-sequence power is determined as such, and the accurate grounding line could be selected by this way.
小電流接地選線采用零序功率方向原理,可選五次諧波電壓、電流或基波電壓、電流計(jì)算,故障相的電容電流落后于U0 90°,而非故障相電容電流超前U0 90°,以此決定零序功率方向的接地選線原理,可準(zhǔn)確的選出接地線路。